EA on a Worcester Bosch Greenstar is a fault code that Worcester’s user guide links to three causes: no or low gas supply, a blocked condensate outlet, or a blocked flue. Check gas and the condensate pipe, reset once, and quote EA and the three-digit number if you call an engineer.
Contents
- 1 What does the EA fault code mean on a Worcester boiler?
- 2 Safe checks Worcester points you to
- 3 When to call Worcester or an engineer
- 4 Repair or replace?
- 5 Why the number under EA matters
- 6 A winter routine that avoids repeat faults
- 7 Time for a new boiler?
- 8 Frequently asked questions
- 9 Related Eco Happy guides
What does the EA fault code mean on a Worcester boiler?
Worcester Bosch’s Greenstar user instructions show EA as a fault code that flashes on the display with a blue operation or fault light. When it appears, the manual says to reset the boiler. It also asks you to quote the alert code and the three-digit number under it, for example “EA and 227”, when contacting Worcester about a fault.
In Worcester’s fault finding table for the Greenstar i System, an EA code flashing on the display has three listed causes: no gas supply or low gas supply pressure, a blocked condensate outlet and a blocked flue. The remedies are to contact your gas supplier, to check the condensate pipe outlet for blockages such as ice or foreign objects if it is safe to do so, and to check the flue outlet for damage or blockage if it is safe to do so.
Newer boilers such as the Greenstar 4000 show a message on the display with a numeric fault code (the user guide’s own example is code 232) instead of the older two-letter codes. Worcester’s installation manual for the Greenstar i ErP lists EA 227 as “no ionisation detected after ignition” and EA 229 as “loss of ionisation signal during operation”, so 227 means the boiler could not prove a flame when lighting and 229 means the flame was lost while running. Meanings can vary between models, so check the manual for your boiler.
Safe checks Worcester points you to
- Check you have gas. Worcester’s fault finding table asks you to check other gas appliances and whether a prepayment meter has run out of credit.
- Check the condensate pipe outlet for ice or foreign objects, if it is safe. A frozen or blocked condensate pipe will cause the boiler to shut down, says the manual. Thaw it with a hot water bottle, a microwaveable heat pack or a cloth soaked in hot water against the pipe near the blockage, or pour hot but not boiling water from a watering can. Never use boiling water, and only thaw a pipe at ground level that is easy to reach. Take care of slip hazards where thawed water could re-freeze.
- Check the flue outlet from the ground for damage or blockage. Do not climb to inspect it.
- Reset the boiler. On a Greenstar i or CDi Compact, press the reset button once. The display briefly shows Reset, and if it worked the boiler returns to normal. On a Greenstar 4000, the guide says to press the two navigation keys until Reset shows. After thawing a pipe the manual says to reset and wait two or three minutes for the boiler to restart.
If the reset does not work, Worcester says the code will return and the blue light will keep flashing, and some codes cannot be cleared by a simple reset because of internal safety systems.
Gas Safe warning
Do not open the boiler casing or touch gas, flue or other internal parts. Anything inside the boiler, including gas valves, burners, electrodes, fans, heat exchangers and circuit boards, must be dealt with by a Gas Safe registered engineer. If you smell gas, suspect a gas leak or flue fumes, or a carbon monoxide alarm sounds: turn off the gas at the meter if it is safe to do so, open doors and windows, do not use light switches or anything electrical, leave the property and call the National Gas Emergency Service on 0800 111 999.
When to call Worcester or an engineer
The manual’s advice is that if a fault cannot be reset by you, a service engineer visit is necessary. Call an engineer if:
- EA returns after a reset.
- Your gas supply is fine, the condensate pipe is clear and the flue looks undamaged, but the boiler still will not run.
- You can smell fumes, or a CO alarm sounds.
Have the code, the three-digit number, the boiler model and the date of the last service ready. Worcester’s guarantee terms state that no charge is made for parts or labour within the guarantee period if the boiler has been regularly serviced at least once a year, so keep your service record. Our Worcester fault codes guide lists other codes.
Repair or replace?
If your Worcester is within its guarantee and serviced, ask Worcester first. If it is older, compare repair quotes with the cost of a new boiler and consider how many faults you have had. See boiler beyond economical repair, and Worcester Bosch boiler prices if you are comparing.
Why the number under EA matters
Greenstar boilers display a code and a three-digit number together, and Worcester’s technical teams use the number to identify the exact fault. That is why the manual asks you to quote both. If your boiler only shows a number, as newer models do, write it down exactly. Take a photo of the screen if you can. Engineers can look up the number in the installation manual for your model and go to the right component first, which saves time on site.
A winter routine that avoids repeat faults
- Know where your condensate pipe runs and insulate exposed sections.
- Keep heating on a low setting during a hard frost.
- Check prepayment credit before the evening.
- Keep the flue terminal clear of plants and debris.
- Book the annual service, which also protects the guarantee.
Time for a new boiler?
If your Worcester is old and keeps locking out, a new boiler may cost less than the next repair. Eco Happy fits new combi boilers from £1,928.99 fully fitted including VAT, with a Gas Safe registered engineer, the old boiler removed and a fixed price you can see online before you commit. Get my fixed boiler price in about a minute, or call 0114 387 7066. Boiler finance is available through a panel of lenders at 11.9% APR representative, subject to status (see boiler finance). Rated 4.6 Excellent, over 650 reviews on Trustpilot.
Frequently asked questions
What does EA mean on a Worcester Bosch boiler?
It is a fault code. Worcester’s guide lists no or low gas, a blocked condensate outlet and a blocked flue as causes.
What is EA 227?
Worcester’s Greenstar i ErP installation manual lists EA 227 as no ionisation detected after ignition: the boiler tried to light but could not prove a flame. Quote the alert code and the three-digit number, such as EA and 227, to Worcester or your engineer.
How do I reset a Worcester boiler showing EA?
On a Greenstar i or CDi Compact, press reset once. On a Greenstar 4000, use the keys described in the user guide until Reset shows.
Can a frozen condensate pipe cause EA?
Yes. Worcester says a frozen or blocked condensate pipe will make the boiler shut down. Thaw it with hot but not boiling water if it is safe.
Is EA dangerous?
It is a safety shutdown. If you smell gas, leave the property and call the National Gas Emergency Service.
Who should I call if EA keeps returning?
A Gas Safe registered engineer, or Worcester if the boiler is under guarantee and serviced.
Related Eco Happy guides
- Worcester Bosch fault codes: the full hub
- How to reset a Worcester boiler
- Condensate pipes
- Boiler lockout explained
- Worcester Bosch Greenstar 4000
- Worcester Bosch boiler prices
- Eco Happy boiler advice hub
Eco Happy Installs Limited (FRN 1051640) is a credit broker working with a panel of lenders. We are authorised and regulated by the Financial Conduct Authority as a credit broker, not a lender. The availability of finance and the terms offered will depend on your individual circumstances. Credit is subject to status, affordability and lender approval. Terms and conditions apply.