Tom Allan

Published November 24, 2026

Last Updated on November 24, 2026

Last Updated on November 24, 2026

Updated 24 November 2026 · Written by Tom Allan, Eco Happy (Gas Safe registered)

Baxi E1 Error Code: What It Really Means

  • ⭐ Trustpilot 4.6 Excellent, over 650 reviews
  • Gas Safe registered: 973154
  • Price match on like-for-like quotes

Quick answer

On most Baxi boilers, E1 is not a code on its own. The display alternates E1 with two more digits, so E133 appears as E1 then 33. Read the full number: E118 is low pressure, E133 is a gas supply, ignition or flame fault, and E110 is overheating.

Why Baxi boilers show “E1”

Searching for “Baxi E1” is very common, and the confusion is understandable. The manual for Baxi Heating UK boilers (published for the Potterton Promax range, which uses the same display) explains it: the codes are two or three digits preceded by the letter E, and a code such as E133 is displayed by “E1” alternating with “33”. A two-digit code such as E50 is shown as “E” then “50”.

So if your display flashes E1, wait and watch. The next characters will tell you which code you actually have. Write down the whole number before you do anything else, because the right action depends entirely on it. If you can honestly see only “E1” and nothing follows, note that some newer Baxi 200 to 800 series boilers use a different format that starts E.01 (for example E.01.17, no water circulation), and you should check the manual for your model.

The most common Baxi codes that start with E1

CodeWhat Baxi saysWhat you can safely do
E110Boiler maximum temperature exceeded or safety thermostat tripped (possible jammed pump or air in the circuit)Check pressure, then reset once. If it returns, call an engineer.
E118Water pressure low (below 0.5 bar)Repressurise to between 1 and 2 bar. If it keeps dropping, suspect a leak.
E119Water pressure switch not operated on some models; Baxi also lists it among codes that can be caused by a frozen condensate pipeCheck pressure and the condensate pipe, then reset once.
E125Water circulation faultEngineer needed.
E128Frequent loss of flameCheck the condensate pipe, then call an engineer.
E130Flue thermostat or flue sensor tripped (lockout)Reset once. If it repeats, call an engineer.
E133Gas supply, ignition or flame failureCheck gas, prepayment credit and condensate pipe, then reset once.
E160Fan faultEngineer needed.

These meanings come from Baxi’s published error code table and its user guides. Exact numbers and descriptions vary between models and ages, so always check your own manual.

E118 or E119: low pressure

Baxi Heating’s user guide for the Potterton Promax (which uses the same display) says the central heating system pressure should be between 1 and 2.5 bar, normally between 1.0 and 1.5 bar, and that a reading below 1 bar means you should repressurise. Below 0.5 bar the boiler shows E118 (or E119 on some models).

  1. With the boiler off and cold, check the gauge. On some models you can show the pressure on the display by pressing a button repeatedly, which your user guide describes.
  2. Connect the filling loop, which is two taps and a separate copper or flexible pipe. Fully open one tap first, then carefully open the second while watching the gauge.
  3. When the needle reads between 1 and 2 bar, close both taps. Baxi’s guide says to disconnect and remove a temporary filling pipe and keep it somewhere safe.
  4. Reset the boiler if the code is still showing.

If you have to do this regularly, Baxi says the system may have a leak. Read our repressurising guide and the page on boilers losing pressure.

E133: gas, ignition and the frozen condensate pipe

Baxi describes E133 as a problem with the gas supply, ignition or flame detection, or a blocked condensate pipe. Baxi’s website says E133, E119 and E128, among others, can mean your condensate pipe is frozen. Its steps are:

  1. Switch the boiler off at the control panel and turn off the electricity at the wall.
  2. Find the frozen section, usually the most exposed part of the pipe.
  3. Warm it along its exposed length with a hot water bottle, a microwaveable heat pack or warm water from a watering can. Do not use boiling water.
  4. Turn the power back on and restart the boiler. Repeat until it runs.

Also check that gas is available: does your hob work, and is a prepayment meter in credit? Then reset the boiler. Our condensate pipes guide explains why they freeze.

How to reset a Baxi boiler

On a Baxi with a selector switch, open the pull-down panel, turn the selector to R (Reset), hold for at least five seconds and release. The fault code is replaced with the boiler temperature, and the burner should light after a few seconds. Baxi’s guidance is that if lockouts happen frequently, a fault is indicated and you should contact your installer or service engineer. One reset is fine. Repeated resets are not a fix.

Gas Safe warning

Do not open the boiler casing or touch gas, flue or other internal parts. Anything inside the boiler, including gas valves, burners, electrodes, fans, heat exchangers and circuit boards, must be dealt with by a Gas Safe registered engineer. If you smell gas, suspect a gas leak or flue fumes, or a carbon monoxide alarm sounds: turn off the gas at the meter if it is safe to do so, open doors and windows, do not use light switches or anything electrical, leave the property and call the National Gas Emergency Service on 0800 111 999.

When to call an engineer

  • The same code returns after one reset.
  • You see E125, E160 or any code that points to a component (pump, fan, sensors).
  • Pressure keeps dropping after you top it up.
  • You smell gas, or a carbon monoxide alarm sounds. Leave the property first.

If the boiler is under 10 years old and still has a manufacturer warranty, check the terms before booking, since an unapproved repair can affect cover.

If it is an older Baxi that has thrown several codes this winter, compare the repair against a replacement. Our beyond economical repair guide helps you judge.

Time for a new boiler?

If your Baxi keeps throwing E1 codes, an engineer’s repair bill can add up quickly. Eco Happy fits new combi boilers from £1,928.99 fully fitted including VAT, with a Gas Safe registered engineer, the old boiler removed and a fixed price you can see online before you commit. Get my fixed boiler price in about a minute, or call 0114 387 7066. Boiler finance is available through a panel of lenders at 11.9% APR representative, subject to status (see boiler finance). Rated 4.6 Excellent, over 650 reviews on Trustpilot.

Prefer to pay monthly? Boiler finance is available through a panel of lenders, subject to status. See boiler finance examples →
Representative example: cash price £2,474.96 (Worcester Bosch Greenstar 4000 25kW). Deposit £0. Amount of credit £2,474.96. 120 monthly payments of £34.51. Total amount payable £4,141.20. Total charge for credit £1,666.24. Representative 11.9% APR. Eco Happy Installs Limited (FRN 1051640) is a credit broker, not a lender, working with a panel of lenders.

Frequently asked questions

What does E1 mean on a Baxi boiler?

E1 on its own is usually the first part of a three-digit code. The display alternates it with the remaining digits, so E133 appears as E1 then 33. Read the full code to know the fault.

What does E118 mean on a Baxi?

Baxi lists E118 as water pressure low, below 0.5 bar. Repressurise to between 1 and 2 bar and check for leaks if it recurs.

What does E133 mean on a Baxi boiler?

Baxi describes E133 as a gas supply, ignition or flame problem, and it can also be caused by a frozen or blocked condensate pipe. Check your gas supply and the pipe, then reset once.

Can I reset a Baxi boiler showing an E1 code?

Yes. Turn the selector to R, hold for at least five seconds and release. If the code returns, stop and call a Gas Safe engineer.

Why does my Baxi boiler keep showing E133 in winter?

A frozen condensate pipe is a common winter cause. Thaw it with warm, not boiling, water at ground level. If it keeps happening, ask an engineer about rerouting or insulating the pipe.

Is this the same as the general E1 boiler error?

Different makes use E1 differently. This page covers Baxi boilers. See our general E1 guide for other brands.

Related Eco Happy guides

Eco Happy Installs Limited (FRN 1051640) is a credit broker working with a panel of lenders. We are authorised and regulated by the Financial Conduct Authority as a credit broker, not a lender. The availability of finance and the terms offered will depend on your individual circumstances. Credit is subject to status, affordability and lender approval. Terms and conditions apply.

Leave a Reply

Your email address will not be published. Required fields are marked *